Hongze pipe

Hongze Valve

One-Stop Supplier for Rubber Joints, Bellows, and Waterproof Casings

EPDM  Expansion Joint

EPDM  Expansion Joint is a highly flexible and durable rubber connector widely used in various industrial piping systems. Designed to absorb vibration, reduce noise, and compensate for thermal expansion, it is especially ideal for HVAC systems, water supply networks, chemical processing plants, and wastewater treatment applications.

Made from premium EPDM (Ethylene Propylene Diene Monomer) rubber, this expansion joint provides outstanding resistance to ozone, UV rays, weathering, and a wide range of chemicals including weak acids and alkalis. Its superior performance in both high and low temperature environments (from -40°C to +120°C) makes it a reliable solution for indoor and outdoor installations.

Available in single sphere and double sphere designs, our EPDM expansion joints come in a variety of sizes and flange types, including ANSI, DIN, BS, and JIS standards. The flexible rubber body helps isolate vibrations from pumps and compressors, while extending the service life of connected equipment.

EPDM rubber expansion joints are also known as **flanged rubber flexible joints**, **rubber bellows**, and **rubber compensators**, making them popular among engineers and distributors searching for reliable and cost-effective pipeline solutions.

Key Features

🔹 **Excellent Flexibility & Vibration Absorption**
Effectively minimizes mechanical stress, vibration, and noise transmission in piping systems.

🔹 **Superior Resistance to Weather & Chemicals**
Made from high-grade EPDM rubber, resistant to ozone, UV, aging, and mild acids/alkalis—ideal for outdoor and industrial applications.

🔹 **Wide Temperature & Pressure Range**
Operates reliably in temperatures from -40°C to +120°C, suitable for low to medium pressure systems.

🔹 **Multiple Design Options Available**
Offered in single sphere, double sphere, flanged, threaded, and union-end types to meet ANSI, DIN, BS, and JIS standards.

🔹 **Corrosion-Resistant Reinforced Flanges**
Flanges are available in carbon steel, stainless steel, or customized alloys to suit different media and environmental conditions.

🔹 **Applications Across Industries**
Widely used in HVAC, cooling towers, water treatment plants, chemical pipelines, and pump systems.

🔹 **Easy Installation & Maintenance**
Compact design allows for simple installation even in tight spaces, reducing time and

Technical Specifications

Nominal Diameter (DN)InchLength (L) mmFlange Thickness (b) mmBolt Qty (n)Bolt Hole Dia. mmBolt Circle Dia. (D1) mmAxial Extension mmLateral Displacement mmAngular Deflection (°)
DN321.25”9516418100699
DN401.5”95184181106109
DN502”1051841812571010
DN652.5”1152041814571311
DN803”1352041816081512
DN1004”15022818180101913
DN1255”16524818210121913
DN1506”18024823240122014
DN2008”21024823295162522
DN25010”230261223350162522
DN30012”245281223400162522
DN35014”255281623460162522
DN40016”255301625515162522
DN45018”255302025565162522
DN50020”255322025620162522
DN60024”260362030725162522
DN70028”260362430840162522
DN80032”260382434950162522
DN90036”2604228341050162522
DN100040”2604428341160182624
DN120048”2604832411380182624
DN140056”3504436341560202826
DN160064”3504640341760253530
DN180072”3505244411970253530
DN200080”4205448482180253530
DN220088”5804052482390253530
DN240096”6104156482600253530
DN2600104”6504260542810253530
DN2800112”6804564543020253530
DN3000120”6805068543220253530

Notes

  1. Customization available upon request with specific drawings or specifications; flanges are based on the “National General Water Supply and Drainage Standard Atlas,” others follow HG/T2289-92.

  2. For DN350-600(2) models, working pressure is 1.6MPa; for DN32-400(3) models, working pressure is 2.5MPa.

  3. For DN700-DN200 models, working pressure is 1.0MPa; for DN1400, working pressure is 0.6MPa; for DN1600-DN1800, working pressure is 0.4MPa, flanges are selected according to 0.6MPa; for DN2000, working pressure is 0.25MPa, flanges are selected according to 0.6MPa pressure.

  4. For high-rise water supply, products above DN200 must have fixed supports or brackets; otherwise, anti-pullout devices should be installed.

ProjectUnitJGD-1JGD-2JGD-3
ModelJGD-1JGD-2JGD-3
Working PressureMPa (kgf/cm²)1.0 (10)1.6 (16)2.5 (25)
Burst PressureMPa (kgf/cm²)2.0 (20)3.0 (30)4.5 (45)
Vacuum ResistanceKPa (mmHg)53.3 (400)86.7 (650)100 (750)
Operating Temperature°C-15 ~ 115°C (Special: -30 ~ 250°C)
Applicable MediaAir, Compressed Air, Water, Seawater, Hot Water, Oil, Acid, Alkali, etc.
MaterialTemperature Range (°C)Oil ResistanceAcid & Alkali ResistanceElasticityAbrasion ResistanceTypical Applications
EPDM-40 ~ 120PoorExcellentExcellentMediumWater, Steam, Air
NR (Natural Rubber)-30 ~ 80PoorMediumExcellentExcellentIndustrial Water, Air
NBR-20 ~ 100ExcellentMediumGoodGoodOil, Lubrication Systems
Neoprene-35 ~ 100GoodGoodMediumGoodSeawater, Mild Chemicals
Silicone-60 ~ 200PoorPoorGoodLowFood Grade, Medical
FKM (Viton)-20 ~ 250ExcellentExcellentMediumExcellentChemical, High Temp Oil
Butyl (IIR)-40 ~ 120PoorGoodExcellentMediumGas, Acidic Gases
1.Inspection Before Installation
•Check whether the rubber joint is damaged, aged, or defective.
•Confirm the model, pressure rating, and flange size match the system requirements.
2.Installation Environment
•Avoid installation under direct sunlight, ozone, or in environments with high temperature or strong corrosive chemicals.
•If outdoor installation is necessary, use UV-protective shields or covers.
3.Installation Instructions
•Align the rubber joint with the center of the pipe flanges. Avoid pulling or twisting during installation.
•Tighten bolts crosswise and evenly to avoid uneven force or deformation.
•Use proper washers and gaskets.
4.Precautions
•Ensure the pipeline is properly fixed; rubber joints are not designed to bear the full weight.
•Do not over-extend, over-compress, or apply excessive torsion to the joint.
•Allow for movement as specified (axial, lateral, angular) within rated limits.
•Install limit rods or anti-pull devices if the pipe system lacks sufficient fixation.
5.Working Pressure & Temperature
•Observe the rated pressure and temperature range during operation.
•Standard range: -15°C to +115°C (or as specified).
6.Routine Inspection & Maintenance
•Inspect every 6–12 months for signs of aging, damage, or leakage.
•Replace if any abnormalities are found.
1. Inspection Before Installation
•Check whether the rubber joint is damaged, aged, or defective.
•Confirm the model, pressure rating, and flange size match the system requirements.
2.Installation Environment
•Avoid installation under direct sunlight, ozone, or in environments with high temperature or strong corrosive chemicals.
•If outdoor installation is necessary, use UV-protective shields or covers.
3.Installation Instructions
•Align the rubber joint with the center of the pipe flanges. Avoid pulling or twisting during installation.
•Tighten bolts crosswise and evenly to avoid uneven force or deformation.
•Use proper washers and gaskets.
4.Precautions
•Ensure the pipeline is properly fixed; rubber joints are not designed to bear the full weight.
•Do not over-extend, over-compress, or apply excessive torsion to the joint.
•Allow for movement as specified (axial, lateral, angular) within rated limits.
•Install limit rods or anti-pull devices if the pipe system lacks sufficient fixation.
5.Working Pressure & Temperature
•Observe the rated pressure and temperature range during operation.
•Standard range: -15°C to +115°C (or as specified).
6.Routine Inspection & Maintenance
•Inspect every 6–12 months for signs of aging, damage, or leakage.
•Replace if any abnormalities are found.

What are the advantages of using EPDM EPDM  Expansion Joint in piping systems?

 EPDM  Expansion Joint offer excellent resistance to ozone, UV, and weathering, making them ideal for both indoor and outdoor installations. They are especially effective in absorbing vibration, reducing system noise, and handling thermal expansion in water, HVAC, and light chemical pipelines.

In which applications are EPDM  Expansion Joint joints most commonly used?

EPDM joints are widely used in HVAC systems, cooling towers, potable water supply, wastewater treatment, and general industrial piping. Their resistance to hot water and mild chemicals makes them suitable for a variety of non-oily media.

What is the temperature and pressure range for EPDM  Expansion Joint?

Our EPDM rubber joints operate reliably in temperatures ranging from -40°C to +120°C, and can withstand working pressures up to 16 bar depending on the size and design. This makes them suitable for both low and medium pressure applications.

Can the flange and reinforcement materials of EPDM  Expansion Joint be customized?

Yes, we offer customization of flanges in carbon steel, stainless steel (SS304/316), or other materials based on your application needs. The internal reinforcement layers can also be adjusted to meet higher pressure or specific media requirements.

Let Us Help With Your Pipeline Needs

Contact Us Now

Let Us Help With Your Pipeline Needs
We respond quickly to inquiries and provide expert support on rubber joints, metal hoses, and customized solutions.

Explore Rubber Expansion Joint Types and Materials

滚动至顶部

Thank you for your inquiry!

Our sales team will contact you via Email or WhatsApp within 24 hours.